Shrnutí obsahu

Strany 1 - SURE-LOCK

SURE-LOCKAll ProUser Manual®

Strany 2 - Proprietary Notice

7THE SURE-LOCK TRANSMITTER(Figure 1-2) 1. OUTPUT FREQUENCIES: Frequencies are selectable combinations of 8.1 kHz, 81 kHz, and 480 kHz, a

Strany 3

814. cm D), typical.15. WEIGHT: 8 lbs. (3.6 kg), typical.16. CONSTRUCTION: Weat

Strany 4 - FUNCTION

9A B C D E FI JGKHFigure 1-2(Transmitter)A. Battery Charger Jack G. DisplayB. Safety

Strany 5 - TABLE OF CONTENTS

10WARNING! SAFETY FIRST!Check for and turn off all power sources before connecting the trans-mitter directly to otherwise power carrying cables.Direc

Strany 6

11A. Signal Power Indicator (SPI) B. Left-Right Indicator C. Battery Status Indicator D. Lock IndicatorE. On-Off/Volume SwitchF. Bubble LevelG

Strany 7 - GENERAL DESCRIPTION

12ControlsThe receiver has several unique features, controls, and indicators with which the operator must become familiar (Figure 1-4).1. DISPLAY: Th

Strany 8

13e. Lock Indicator - The LOCK indicator is a unique feature of Sure-Lock. When the LOCK indicator appears on the display, the receiver is locked to

Strany 9 - (System Components)

14of the operator. The second one is higher in pitch and corresponds to the conductor being to the right of the operator. When the receiver is positio

Strany 10

15CHAPTER IIGENERAL OPERATING PROCEDURESOPERATING PROCEDURESThis portion of the manual is broken down into the TRANSMITTER and RE-CEIVER sections. Th

Strany 11

161. Inductive or Indirect Connect2. Conductive or Direct Connect3. 4. 5.

Strany 12 - (Transmitter Side Panel)

Proprietary NoticeThe contents of this manual are proprietary to Heath Consultants Incorporated. Reproduction of this manual, in whole or in part, is

Strany 13 - SAFETY FIRST!

17One of the pitfalls the operator must recognize is that when the transmitter is functioning in the inductive mode, other conductors in the area may

Strany 14 - (Receiver)

18Figure 2-2(Transmitter positioned on its end directly over the interfering conductor. This position will energize the target conductor and apply min

Strany 15

19Figure 2-3(Transmitter positioned on its end for closer tracing applications. This set-up will reduce the air coupling distance)ConductorTwo Operato

Strany 16

20Figure 2-4(Operators properly positioned to begin the two operator sweep)Figure 2-5(Two operator sweep. The operators have energized and located the

Strany 17

21Conductive (Direct Connect) ModeWhenever possible, the conductive method is preferred for energizing the con-ductor. By using a direct hookup, the o

Strany 18 - GENERAL OPERATING PROCEDURES

22must be aware at all times of where the grounding cables run and what is used as a ground. The cables are carrying the full signal current, and, if

Strany 19

23Two coupler clamps (see USING DUAL COUPLER CLAMPS, page 24) can also be used in Dual Jacking.(Correct - Grounding Application)(Incorrect - Grounding

Strany 20

241. INSTRUCTIONS FOR SINGLE COUPLER CLAMP USE: Before using the coupler clamp, refer to the coupler clamp applications section which 

Strany 21

25allow the signal to propagate.In such situations, this conductor loop must be closed. The coupler clamp comes equipped with a bridging cable which c

Strany 22 - Conductor

26(Correct - Grounding attachment allows signal (Correct. - The coupler clamp jaws are closed around the conductor. The conductor is energized)

Strany 23 - Figure 2-5

SURE-LOCK®Heath Consultants IncorporatedHouston, TX713-844-1300 Fax: 713-844-13091-800-HEATH-USwww.heathus.comHeath...Safety, Leadership, Innovation,

Strany 24

271. ONCE THE CONDUCTOR IS PROPERLY ENERGIZED:a. Turn the receiver on and select the appropriate frequency matching that on the transmitter. 

Strany 25

28 Left Lock RightFigure 2-10

Strany 26

29above indicators) and the receiver is positioned directly above the

Strany 27

30These results may also indicate that the operator should reposition the transmit-ter or go to a different transmitter mode of operation to energize

Strany 28

31CHAPTER IIIMAINTENANCEBATTERY CHARGING AND REPLACEMENT INSTRUCTIONSLow Frequency TransmittersThe Sure-Lock low frequency transmitters are equipped w

Strany 29

32 positive ends of the batteries (opposite the spring ends) to avoid damaging the

Strany 30

33It is suggested that when the Sure-Lock is not in use, it should be kept in its 

Strany 31 - Figure 2-10

341. 12 VDC BATTERY CHARGER (HPN 6710777): Used to charge the transmitter battery from a 12 VDC power source such as a vehicle’s cigarette lighter. O

Strany 32

WARRANTY AND WARRANTY REPAIRSThe Sure-Lock instruments are warranted for two years.All other instruments and products manufactured by Heath Consultant

Strany 33

RETURN AUTHORIZATION (RA)1. Contact Heath Customer Service at 1-800-432-8487 fo

Strany 34 - MAINTENANCE

FUNCTIONThe Sure-Lock® is a state-of-the-art, multi-frequency cable and pipe locator system 

Strany 35

CUSTOMER ASSISTANCE, MANUFACTURING AND SERVICE LOCATIONSCORPORATE HEADQUARTERSHeath Consultants Incorporated9030 Monroe RoadPhone:

Strany 36

Heath...Safety, Leadership, Innovation, PerformanceThen, Now and TomorrowHeath Consultants IncorporatedHouston, TX713-844-1300Fax: 713-844-13091-800-

Strany 37

2TABLE OF CONTENTSFunction ... 1CHAPTER I - GENERAL DESCRIPTIONDescription

Strany 38

3  Using the Receiver ...

Strany 39

4CHAPTER IGENERAL DESCRIPTIONDESCRIPTION OF SYSTEM COMPONENTS(See Figure 1-1) TransmitterThe Sure-Lock® multi-frequency transmitter combines numerous

Strany 40

5Coupler Clamp (Optional)An alternate direct method of energizing the conductor is with a coupler clamp. This device can be used with the transmitter

Strany 41 - 1-800-HEATH-US

6ABCDEFGHIJKLA. Transmitter G. Grounding PlateB. Receiver H. Grounding Spike D. Manual J. Conductive Cabl